Real CPAP runtimes on power stations (owner reports)
Everything else on this site is formula math: capacity x 0.85, divided by ResMed's published draws. This page is the other half - what owners actually measured, collected from public forum threads on 2026-11-14, source link on every report. Owner reports, not our measurements, and not medical advice.
Headline reports

The 66-hour log: EcoFlow DELTA 2, dry, on DC
The cleanest long log in the set. A DELTA 2 (1,024 Wh), an AirSense 11, a DC adapter, humidifier and heated tube off, pressure 9: 66 hours over 9 nights, 9% left. Implied full-pack runtime about 72.5 hours vs 79.1 predicted on the humidifier-off preset. In the owner's words:
After running it for 9 nights and exactly 66 hours of runtime on my CPAP the power station was down to 9% battery.
EcoFlow River 2 Pro: same machine, AC vs DC
One owner, one AirSense 11, heated humidifier and tube on, 8 hours a night, run twice: 423 Wh on AC, 300 Wh on DC. The owner's math: DC was 29% more efficient.
On household AC, the power station had 44.9% remaining the next morning, meaning it consumed about 423 Wh.
However, using the Car adapter leaves 60.9% remaining, or 300 Wh consumed, which means I can get 2 full nights from this power station.


Two Jackery 1000-class tests: the heated presets hold up
Humidifier on, the presets track. A Jackery Explorer 1000 v2 (AirSense 10, humidity 7, AC) used 33% in about 6.5-7 hours - implied 20.45 hours vs 20.67 predicted at the 44 W preset. A Jackery Explorer 1000 Plus (AirSense 11, heat on auto, AC) used 33% of its main pack in 8 hours - implied 24.24 hours vs 24.43 predicted.
Buy on Amazon: Explorer 1000 v2 Buy on Amazon: Explorer 1000 Plus

BLUETTI AC180 at humidity 2, on DC
A mid-humidifier DC run that lands on the 28 W preset: 7.5 hours, 80% left - implied 37.5 hours vs 35.0 predicted.

Anker SOLIX C300: a one-night dry-DC machine
The smallest station in the set (288 Wh): dry on DC, owners used 23% and 21% of the pack per night of about 8 hours; one logged 39 hours (5 nights) dry before reaching 2%. With humidifier and tube heat on, a DC test lasted 6 hours - heat separates several nights from part of one.

The honesty check: BLUETTI AC70, humidifier at 0, on AC
The report that qualifies our own calculator. A BLUETTI AC70 (768 Wh) ran a CPAP on AC, humidifier fitted but set to 0 - the setup our humidifier-off preset prices at 11 W, predicting roughly 59 hours. Instead: 36 points gone in 8.5 hours, implied draw about 32 W, implied runtime about 23.6 hours, owner's estimate about two nights per charge. The plain version: on AC, do not budget 11 W just because the humidifier is turned down to 0 - our calculator now says so next to its results.
The humidifier was present but set to 0. Ran the CPAP for 8 1/2 hours. When I woke up the charge was 59%.
What the reports say overall
- DC beats AC, by a lot. A second pair (Jackery Explorer 1000 v2, AirCurve 10, consecutive nights): 40% of the pack in 7:10 on AC, 30% in 7:41 on DC. Caveat: a cheap aftermarket converter ran one owner empty in about 7 hours, worse than their AC night.
- With the humidifier on, the presets track: Jackery tests within a few percent of 44 W, the AC180 humidity-2 run within a few percent of 28 W, heat-on-auto closer to 44 W than the 56.1 W maximum. Dry on DC often beats the 11 W preset (several packs implied 7-9 W); dry on AC can be far worse (AC70, above).
- Sizing, in owner terms: a 1,000 Wh-class station is the practical one-week box for dry DC running; 700-1,150 Wh the realistic heaters-on weekend box; 288 Wh one dry DC night.
All 41 published reports
Every high- or medium-confidence report, in the order collected. "Implied full-pack runtime" is arithmetic on the owner's figures - hours divided by percent of pack used - labeled as implied wherever it appears.
| Power station | CPAP | Settings | Power path | What the owner reported | Source |
|---|---|---|---|---|---|
| EcoFlow DELTA 2 Buy on Amazon | unspecified (owner measured 55 W) | Humidifier: unspecified (55 W draw implies heat/humid on) Heated tube: unspecified | AC (implied; owner used naive Wh/W math) | 13.5 hours reported implied full-pack runtime ≈ 13.5 h | Reddit thread |
| EcoFlow DELTA 2 Buy on Amazon | ResMed AirSense 11 | Humidifier: off Heated tube: off Pressure: 9 | DC | 66 hours reported 9 night(s) used 91% of the pack implied full-pack runtime ≈ 72.53 h | Reddit thread |
| EcoFlow DELTA 2 Buy on Amazon | ResMed AirCurve 10 VAuto | Humidifier: on (heated humidifier; setting not stated) Heated tube: on (setting not stated) | AC | 7 hours reported 1 night(s) used 22% of the pack implied full-pack runtime ≈ 31.82 h | Reddit thread |
| EcoFlow DELTA 2 Max Buy on Amazon | unspecified | Humidifier: unspecified Heated tube: unspecified | AC (implied: 'plugged in') | 1 night(s) used 13% of the pack implied full-pack runtime ≈ 61.54 h | Reddit thread |
| EcoFlow DELTA 3 Plus Buy on Amazon | unspecified ('just the machine') | Humidifier: unspecified Heated tube: unspecified | AC (implied by inverter-loss comparison in thread) | 8 hours reported 1 night(s) used 45% of the pack implied full-pack runtime ≈ 17.78 h | Reddit thread |
| EcoFlow RIVER 3 Buy on Amazon | ResMed AirSense 10 AutoSet | Humidifier: unspecified Heated tube: unspecified | AC (mains outlet) | 2 (estimated from 100 Wh/night) | Apnea Board thread |
| EcoFlow RIVER 3 Buy on Amazon | ResMed AirSense 10 | Humidifier: off Heated tube: off | DC | 3 night(s) | Reddit thread |
| EcoFlow RIVER 3 Buy on Amazon | unspecified ('old cpap') | Humidifier: unspecified Heated tube: unspecified | AC | 8 hours reported 1 night(s) used 63% of the pack implied full-pack runtime ≈ 12.7 h | Reddit thread |
| EcoFlow River 2 Pro Buy on Amazon | ResMed AirSense 11 | Humidifier: on (heated humidifier) Heated tube: on | AC | 8 hours reported 1 night(s) used 55.1% of the pack (423 Wh) implied full-pack runtime ≈ 14.52 h | Reddit thread |
| EcoFlow River 2 Pro Buy on Amazon | ResMed AirSense 11 | Humidifier: on (heated humidifier) Heated tube: on | DC | 8 hours reported 1 night(s) used 39.1% of the pack (300 Wh) implied full-pack runtime ≈ 20.46 h | Reddit thread |
| EcoFlow River 2 Pro Buy on Amazon | unspecified (same setup as OP, heaters on) | Humidifier: on Heated tube: on | DC | 14 hours reported 2 night(s) | Reddit thread |
| EcoFlow River 2 Pro Buy on Amazon | unspecified (heaters on) | Humidifier: on Heated tube: on | DC (same setup) | 12 hours reported ~1.5 (ran out 4 h into night 2 after 8 h+ night 1) implied full-pack runtime ≈ 12 h | Reddit thread |
| EcoFlow River 2 Pro Buy on Amazon | ResMed AirSense 11 | Humidifier: on Heated tube: on (temperature on) | AC | 9 hours reported 1 night(s) used 43% of the pack (330 Wh) implied full-pack runtime ≈ 20.93 h | Apnea Board thread |
| EcoFlow River 2 Pro Buy on Amazon | ResMed AirSense 11 | Humidifier: unspecified for this poor-converter night Heated tube: unspecified | DC (poor aftermarket converter, later returned) | 7 hours reported 1 night(s) used 100% of the pack implied full-pack runtime ≈ 7 h | Apnea Board thread |
| EcoFlow River 2 Pro Buy on Amazon | unspecified | Humidifier: off Heated tube: off Pressure: 9 cmH2O | DC | 7 night(s) used 80% of the pack | CPAPtalk thread |
| Jackery Explorer 1000 v2 Buy on Amazon | ResMed AirSense 10 | Humidifier: auto Heated tube: unspecified (not mentioned) | AC ('the regular plug') | 10 hours reported used 58% of the pack implied full-pack runtime ≈ 17.24 h | Reddit thread |
| Jackery Explorer 1000 v2 Buy on Amazon | ResMed AirSense 10 | Humidifier: 7 (high; scale usually goes to 8) Heated tube: unspecified (not mentioned) | AC | 6.75 hours reported 1 night(s) used 33% of the pack implied full-pack runtime ≈ 20.45 h | Reddit thread |
| Jackery Explorer 1000 v2 Buy on Amazon | unspecified (humidifier and heat on auto) | Humidifier: auto Heated tube: auto (heat on auto) | AC | 1 night(s) used 37.5% of the pack implied full-pack runtime ≈ 21.33 h | Reddit thread |
| Jackery Explorer 1000 v2 Buy on Amazon | unspecified (humidifier and heat on auto) | Humidifier: auto Heated tube: auto (heat on auto) | DC (12V adapter) | 1 night(s) used 22.5% of the pack implied full-pack runtime ≈ 35.56 h | Reddit thread |
| Jackery Explorer 1000 v2 Buy on Amazon | ResMed AirCurve 10 BiPAP | Humidifier: on (settings as normal) Heated tube: on (heater and all settings as normal) | AC | 7.17 hours reported 1 night(s) used 40% of the pack implied full-pack runtime ≈ 17.92 h | Reddit thread |
| Jackery Explorer 1000 v2 Buy on Amazon | ResMed AirCurve 10 BiPAP | Humidifier: on Heated tube: on (same as-normal settings) | DC | 7.68 hours reported 1 night(s) used 30% of the pack implied full-pack runtime ≈ 25.6 h | Reddit thread |
| Jackery Explorer 1000 Plus Buy on Amazon | ResMed AirSense 11 | Humidifier: auto Heated tube: auto (heat on auto) | AC | 8 hours reported 1 night(s) used 33% of the pack implied full-pack runtime ≈ 24.24 h | Reddit thread |
| Jackery Explorer 1000 Plus Buy on Amazon | ResMed AirSense 10 | Humidifier: unspecified Heated tube: unspecified | AC | ~3.5 (10% per day) used 10% of the pack implied full-pack runtime ≈ 80 h | Reddit thread |
| Jackery Explorer 240 Buy on Amazon | ResMed AirSense 10 | Humidifier: off Heated tube: off (not mentioned; no humidity) | DC | 30 hours reported 4 night(s) implied full-pack runtime ≈ 30 h | Reddit thread |
| Jackery Explorer 240 Buy on Amazon | ResMed AirSense 10 | Humidifier: moderate, about 4 Heated tube: unspecified Pressure: 10 cmH2O fixed | unspecified for this humid test (same owner used DC on the dry test) | 6 hours reported implied full-pack runtime ≈ 6 h | Reddit thread |
| Jackery Explorer 300 Buy on Amazon | unspecified (thread is about Explorer 300; commenter said I use it) | Humidifier: off Heated tube: off | DC | 2-3 night(s) | Reddit thread |
| Jackery Explorer 300 Buy on Amazon | unspecified (same commenter as the 2-3 night DC row) | Humidifier: on Heated tube: on | AC | 7 hours reported implied full-pack runtime ≈ 7 h | Reddit thread |
| Jackery Explorer 300 Buy on Amazon | ResMed AirSense 10 | Humidifier: off Heated tube: off | DC | 3 night(s) | Reddit thread |
| Jackery Explorer 300 Buy on Amazon | ResMed AirSense 10 | Humidifier: off Heated tube: off | DC | 8 hours reported 1 night(s) used 40% of the pack implied full-pack runtime ≈ 20 h | Reddit thread |
| Jackery Explorer 500 Buy on Amazon | ResMed AirSense 10 | Humidifier: on (setting not stated) Heated tube: unspecified | unspecified | 1 night(s) used 35% of the pack implied full-pack runtime ≈ 22.86 h | Reddit thread |
| Anker SOLIX C300 Buy on Amazon | unspecified (9 cm airflow; humidifier off) | Humidifier: off Heated tube: off Pressure: 9 cm (stated as 9 can airflow) | DC (car adapter); C300 DC model | 8 hours reported 1 night(s) used 23% of the pack implied full-pack runtime ≈ 34.78 h | Reddit thread |
| Anker SOLIX C300 Buy on Amazon | ResMed AirSense 10 | Humidifier: off Heated tube: off | DC (cigarette adapter); C300 DC, Bluetooth and WiFi off | 8.1 hours reported 1 night(s) used 21% of the pack implied full-pack runtime ≈ 38.57 h | Reddit thread |
| Anker SOLIX C300 Buy on Amazon | ResMed AirSense 10 | Humidifier: on Heated tube: on Pressure: average 8; 27 L/min mask leak | DC (12V receptacle) | 6 hours reported implied full-pack runtime ≈ 6 h | Reddit thread |
| Anker SOLIX C300 Buy on Amazon | ResMed AirSense 10 | Humidifier: off Heated tube: off Pressure: average 8; 27 L/min mask leak | DC (12V receptacle) | 39 hours reported 5 night(s) used 98% of the pack implied full-pack runtime ≈ 39.8 h | Reddit thread |
| Anker SOLIX C300 Buy on Amazon | Philips DreamStation | Humidifier: off Heated tube: off | DC (12V receptacle) | 32 hours reported 4 night(s) used 57% of the pack implied full-pack runtime ≈ 56.14 h | Reddit thread |
| BLUETTI AC70 Buy on Amazon | unspecified | Humidifier: present but set to 0 Heated tube: unspecified (not mentioned) | AC | 8.5 hours reported 1 night(s) used 36% of the pack implied full-pack runtime ≈ 23.61 h | Reddit thread |
| BLUETTI EB3A Buy on Amazon | ResMed AirSense 10 | Humidifier: off Heated tube: off | DC | 1 night(s) used 27% of the pack implied full-pack runtime ≈ 29.63 h | Reddit thread |
| BLUETTI AC180 Buy on Amazon | unspecified (later posts by same user specify ResMed 11) | Humidifier: on Heated tube: on | DC | 14 hours reported 2 night(s) implied full-pack runtime ≈ 14 h | Reddit thread |
| BLUETTI AC180 Buy on Amazon | unspecified (same settings and same owner as the 2x7 h DC row) | Humidifier: on Heated tube: on | AC | 7 hours reported 1 night(s) used 60% of the pack implied full-pack runtime ≈ 11.67 h | Reddit thread |
| BLUETTI AC180 Buy on Amazon | unspecified | Humidifier: 2 Heated tube: off | DC | 7.5 hours reported 1 night(s) used 20% of the pack implied full-pack runtime ≈ 37.5 h | Reddit thread |
| BLUETTI AC180 Buy on Amazon | ResMed AirSense 11 | Humidifier: on Heated tube: on | DC | 3 night(s) | Reddit thread |
How this page was put together
Collected on 2026-11-14 from public threads on Reddit, the Apnea Board and CPAPtalk stating a station, a CPAP, settings, and a measured outcome; each row links to its thread. Only high- or medium-confidence reports are published - five low-confidence reports from the 46 are not in the table. One is excluded by name: a Jackery Explorer 1000 Plus report of 1% of the pack per night on DC (about 1.7 W - not a plausible CPAP draw; a state-of-charge display error) is not published as a runtime anywhere on this site. Nothing here is a hands-on test by us, and none of it is medical advice: if you cannot safely miss therapy, size up, test at home first, and plan outages with your sleep clinic. The formula side: the CPAP runtime guide and the CPAP runtime calculator.